Restore All System Data

If required, all system backup data can be restored (including the latest UHH files from the last UHH file backup).

Option: Uninstall the Data Reviewer (including addition folders and files) and install again. Once installed, make sure that these Windows Services are available and started:

  • Elasticsearch
  • Reviewer Client
  • Reviewer API+SPA
  1. Stop these Windows services:
    • Elasticsearch
    • Reviewer Client
    • Reviewer API+SPA
  2. Restore the last backup of the Reviewer folder to <install Path>\ProgramData\Eurotherm\Reviewer (overwrite the Reviewer folder).
  3. Restore the latest UHH files:
    1. Go to the last backup of the archive folder.
    2. Select all the UHH files that were created after the last backup of the Reviewer folder.
    3. Copy or move the UHH files to the InBoxFast folder.
  4. Start the services that were stopped in step 3.
  5. Open the Data Reviewer.

When the Data Reviewer opens, log in normally. All system data has been restored to the last backup date of the Reviewer folder. The UHH files (archive folder) have been restored up to the last archive folder backup date.