Totalizers
A totalizer channel allows the running total for any input or math channel to be recorded.
Within EPM Data Management up to 128 totalizer channels can be configured.
Note - The output value of a totalizer is defined as non-volatile (NVOL) data and is saved to the EPM device on-board memory, this ensures it is not lost during a loss of power.
Tip - It is possible to totalize multiple input channels, by combining them in a Math channel, see Adding a Maths Channel for details.
The totalizer equation is tott= tott-1+(mat/(TUxSF)).
where:
-
tott = totalizer value this sample
-
tott-1 = totalizer value last sample
-
mat= value of totalized channel this sample
Note - Time between samples = Recording interval set in Group configuration, see Configuring Groups Settings for details. -
TU = Time Unit
-
SF = Scaling Factor
Totalizers are commonly used to record flow rates.
Related topics - Configuring a Totalizer Channel, Sorting and Filtering Totalizers, Editing a Totalizer Channel, Deleting a Totalizer Channel and Using the Totalizers Operator Panel.
Last Update - March 2026